Medical Titanium Parts CNC Machining
Medical Titanium Parts — Precision CNC Machining for Complex Titanium Components
We machine medical titanium parts (Grade 2 / 5 / 23) from prototype to repeat production, with tight tolerances, controlled documentation, and export-ready inspection records.
Send your 2D + 3D files to get an RFQ. (STEP/IGES/X_T + PDF/DWG)
Why procurement and engineering teams choose us for medical titanium parts
AXALLOY Precision is a Shenzhen-based CNC machining partner focused on difficult-to-machine alloys, especially titanium used in medical and precision equipment. We're a strong fit when your program needs more than "a shop that can cut metal"—you need process control, predictable communication, and documentation you can pass to Quality.
Best-fit use cases
- Tight GD&T, thin walls, and critical interfaces
- Complex milled or mill-turned titanium components requiring fewer setups
- Programs being transferred from an unreliable supplier
- Prototype builds that must scale to controlled repeat orders
What we optimize for
- Manufacturability + stable process route
- Inspection strategy aligned to critical features
- Traceability and project-specific quality records
- Reliable delivery and responsive support for international teams
Titanium grades we machine for medical applications
If you have a specific standard or callout on the drawing, include it in your RFQ and we will align the machining and inspection plan to your requirements.
-
Titanium Grade 2
Commercially pure titanium for corrosion resistance and biocompatibility
-
Titanium Grade 5 (Ti-6Al-4V)
Industry-standard high-strength alloy for structural medical components
-
Titanium Grade 23 (Ti-6Al-4V ELI)
Extra-low interstitial grade for enhanced fracture toughness and biocompatibility
Capabilities for medical titanium parts (prototype → production)
We support programs from 1–10,000+ parts, including high-mix repeat manufacturing.
CNC milling (3/4/5-axis)
For housings, brackets, plates, complex structural parts, contoured features, thin walls, and precision interfaces.
- Milling tolerance: down to ±0.005 mm
- Min. internal corner radius: R0.3 mm
- Surface finish: Ra 0.8 μm
Turning and mill-turn
For rotational components requiring strong feature relationships and fewer setups (connectors, nozzles, sleeves, valve-style geometries).
- Turning tolerance: down to ±0.005 mm
- Concentricity: down to 0.008 mm
- Mill-turn: up to 9 axes, live tooling to 12,000 rpm
EDM and precision grinding
When the geometry demands it.
- Wire EDM: accuracy ±0.005 mm
- Sinker EDM: min. corner radius R0.05 mm
- Grinding: tolerance ±0.002 mm, finish Ra 0.2 μm
Supported special processes
As required by your application.
- Heat treatment coordination
- Passivation, coating, deburring
- Marking, cleaning, assembly support
Typical tolerances, finishes, and part constraints
Our typical capability range for medical titanium parts includes:
±0.010 mm
Standard tolerance
±0.005 mm
Precision tolerance
0.005 mm
Flatness (grinding tighter)
0.010 mm
Position tolerance
Ra 0.2 μm
Ground finish
0.5 mm
Min. wall thickness
Ø0.5 mm
Min. machined hole
M1.0
Min. thread (M0.8 Swiss)
If your drawing is tighter than these ranges, send it anyway—critical features can often be achieved with the right process chain and inspection plan.
Inspection, traceability, and quality documentation
Medical titanium parts often fail supplier qualification not because of machining, but because of missing evidence. We plan inspection and records early so Quality isn't chasing documents at shipment.
Inspection capability highlights
- CMM measuring range: 700 × 1,000 × 600 mm
- CMM accuracy: up to 1.8 + L/300 μm
- Optical measurement accuracy: ±0.002 mm
- Temperature-controlled inspection room
- Thread inspection: gauges + optical measurement
- Surface roughness measurement: Ra 0.05–40 μm
Common deliverables
- Material Test Report / Mill Test Certificate
- Certificate of Conformance (CoC)
- First Article Inspection (FAI) report
- Ballooned drawing + full dimensional report
- Surface roughness report (when required)
- Special-process records (when applicable)
- Lot traceability records
What we need from you to quote accurately
To generate a clean RFQ response, please send:
- 13D model (STEP/STP, IGES/IGS, X_T/X_B, SLDPRT, SAT)
- 22D drawing (PDF/DWG/DXF) with GD&T, notes, and revision
- 3Material (e.g., Ti Gr5 / Gr23) and any spec callouts
- 4Quantity (prototype + annual/forecast if available)
- 5Target date and shipping destination
- 6Required documentation (FAI, full dimensional, MTR, CoC, etc.)
- 7Any critical features you want us to focus on (interfaces, sealing surfaces, thin walls)
RFQ: Medical Titanium Parts
We quote for prototype, low-volume, and repeat production and can support expedited timelines when feasible.
If you share your drawing and 3D model, we'll respond with a quote and—when helpful—DFM feedback to reduce risk in titanium machining while protecting your critical dimensions.
Send your RFQ package
- Parts name + revision
- Titanium grade
- Quantity (now + later)
- Required tolerances / critical features
- Required documents (MTR/FAI/dimensional/etc.)
- Target ship date
- Files attached (STEP + PDF preferred)
Request a Quote
Tell us about your component requirements and material challenges.
Not the right fit (so you can decide quickly)
We are likely not the best supplier if the project is:
- Commodity parts purchased solely on lowest unit price
- Missing technical requirements (no drawing, unclear material/specs)
- Unverified certification demands or unauthorized component reproduction
Ready to get pricing?
Send your STEP + PDF and quantity, and we'll prepare your RFQ response for medical titanium parts.
Request an RFQ